Hazmat Open-Side Storage Container
The 4-hour hazmat open–side storage container A.H.R.’s #1 Most Sought After Unit
Our hazmat side-open storage containers have the following features
- AH 4-hour rated UL DES U419 walls & ceilings Class 1, Div 2 Compliant
- Drum Capacity: 27
- Sump Capacity: 540.42 gallons
- Wind Force Rating: 150mph
- 20′ long x 8′ wide x 8.5′ tall ISO container
- 14 gauge corrugated steel
- Pyro Chem Monarch PCI-35ABC Dry Chemical Fire Suppression System meets or exceeds NFPA Code 17, 17A, and 30 specifications
- Canarm Explosion-Proof Enclosed Exhaust Fan – 12in giving 1,640 CFM (more than two times that of industry standards)
- Built-in Security 6″ deep steel floor sump for spill containment
- Removable steel non-skid floor grating provides full access to secondary containment
- Interior explosion proof lighting
- Static Grounding system
- 4 top and bottom 4 bottom crane pad eyes
- Forklift pockets
- Premium, high-solids formula with acrylic polymers, resins, fillers, and titanium dioxide pigments white outside paint coating that reflects 92% of solar heat and rays for a cooler inside temp.
- 220V, Single-Phase 50-amp Electrical requirement. We will provide a female SOOW (Service Cord) plug to connect directly into the unit’s power panel. The unit must also be properly grounded by connecting a green ground wire coming out of the power panel to an 8’ copper grounding rod which must be driven down 95 percent in the ground. Each unit will be provided one grounding rod.
- All vent openings are equipped with three hours, UL-listed fire dampers, and foul weather hoods.
AHR’s 4-Hour hazmat side-open storage containers are very capable lockers that feature a unique design with a focus on ease of access to the entire inside of the unit. We have 4 large doors that hinge on each other, creating the entire side of the unit to open. This hazmat side-opening storage container is ideal for customers loading large and heavy items that must be lifted with a forklift. The unit is capable of giving you first-pick access to 5 pallets at once, placed two deep. This design is available in non-fire-rated, 2-hour fire-rated, and 4-hour fire-rated models. We also carry all 3 fire-ratings in our HQ models, reaching 9’6 tall.
Each hazmat open-side storage container is equipped with a fire-suppression system; in the event that the contents are somehow ignited, and a fire breaks out. Working with Pyro-Chem, we have implemented their total flooding, pre-engineered MONARCH dry chemical hazardous material storage building fire suppression system into our fleet. Our Staff is trained and certified to install, maintain, and inspect our fire suppression systems. We have the experience required for this industry.
Containers that have our UL 4-hour fire rating are required for storing hazardous products placed within 10 feet of, or inside an occupied building. Underwriters Laboratories listed approved USG UL419 walls are 7½” thick and weigh about 21 pounds per square foot. We build our fleet by putting your team and products’ safety first!
We won’t leave you in the dark
This hazmat side-opening storage container can be configured in 6 different ways depending on the size and bidirectional fire ratings. Available in
- Drum Capacity: 27 (single stacked)
- Pallet capacity 48″ x 40″: 8
- Sump Capacity: 589 gallons
- Wind Force Rating: 150mph
- Side Door opening: 230″ wide x 84″ tall
- End door opening: 90″ wide x 84″ tall.
- Exterior dimensions: 20′ long x 8′ wide x 8’6″ tall ISO container. The electrical power panel and FSS alarm bell protrude an additional 6-½” giving a total length of 246½”. The optional air conditioner unit if installed protrudes 20″ off the container’s back wall giving a total length of 260″.
- Interior dimensions: 235″ wide (221″ to the exhaust fan) x 92″ deep x 91″ tall (79″ Floor to bottom of the light / 85½” Floor to bottom of the FSS nozzles).
- GVW: 8,100 pounds.
- GVWR: 60,190 pounds.
- Liquid gallon capacity: 1,963.33 gallons.
- Lockable and Weatherproof Construction.
- 14-gauge corrugated steel.
- Pryo Chem Monarch PCI-35ABC Dry Chemical Total Flooding Fire Suppression System. Equipped with an external remote pull station, external audible alarm, and control head micro switch which cut power to the exhaust fan when the system has been activated. Design to meet or exceeds NFPA Code 17-(Standard for Dry Chemical Extinguishing Systems), and NFPA 30-(Flammable and Combustible Liquids Code) Specifications.
- Canarm non-sparking Explosion-Proof Enclosed Exhaust Fan – 12in giving 1,640 CFM which exceeds NFPA 30.18.6.6.1 & NFPA 30.18.6.2.
- Built-in secondary Security 6in deep steel floor sump for spill containment
- Floor grading support beams at 1 ft on Center.
- Galvanized grading is rated at 850 pounds per square foot.
- Removable Steel non-skid Floor Grating Provides Full Access to Secondary Containment.
- Interior Explosion Proof Lighting Class 1, Division 2.
- All applicable placards and stickers that include: No Smoking within 50 feet, NFPA diamond, NPPA Aluminum Flip File Placard, 10-Legend Worded Set, intended use Warning sticker, Warning Over Hang sticker.
- 4 top and bottom 4 bottom crane pad eyes.
- Forklift pockets: 96″ outside to outside of the forklift pockets / 67¾” inside to inside of the forklift pockets / 81½” center of the forklift pocket to center of the forklift pocket / Each forklift pocket is 14″ wide 4¼” tall.
- Premium, high-solids formula with acrylic polymers, resins, fillers, and titanium dioxide pigments white outside paint coating that Reflects 92% of solar heat and rays for a cooler inside temp.
- Vents are equipped with foul-weather hoods.
- Static Grounding system.
- 220V, Single-Phase 50-amp Electrical requirement. Each container will have a Marine Shore Power Inlet, model number RV129R, 50A 125/250Vac male electrical plug pre-installed near the unit’s power panel. We will provide a female Marine Shore Power Inlet, model number ED-RV129, 50A 125/250Vac plug that will need to be connected to a 4-wire SOOW cable. This cable must be provided by the customer. The unit must also be properly grounded by connecting a green ground wire coming out of the power panel to an 8′ copper grounding rod which must be driven down 95% in the ground. Each unit will be provided with one grounding rod and clamp.
- Built to comply with NFPA Code 17, 17A, 30, and 70 Specifications. Approved holding of hazardous and flammable materials in accordance with local regulations.
- AH 4-hour rated UL DES U419 / MEA 81-98-M walls & ceilings Class 1, Division 2 Compliant.
- Drum Capacity: 27.
- Pallet capacity 48″ x 40″: 8.
- Sump Capacity: 540.42 gallons.
- Wind Force Rating: 150mph.
- Side Door opening: 224″ wide x 84′ tall.
- End door opening: 92″ wide x 84′ tall.
- Exterior dimensions: 20ft long x 8ft wide x 8½ft tall ISO container. The electrical power panel and FSS alarm bell protrude an additional 6-½” giving a total length of 246-½”. The optional air conditioner unit if installed protrudes 15″ off of the container’s back wall giving a total length of 255″.
- Interior dimensions: 216″ wide (201-½ to the fan) x 82″ deep x 86″ tall (74″ Floor to bottom of the light / 80½” Floor to bottom of the FSS nozzles).
- GVW: 13,500 pounds.
- GVWR: 60,190 pounds.
- Liquid gallon capacity: 1,800 gallons.
- Lockable and Weatherproof Construction.
- 14-gauge corrugated steel.
- Pryo Chem Monarch PCI-35ABC Dry Chemical Total Flooding Fire Suppression System. Equipped with an external remote pull station, external audible alarm, and control head micro switch which cut power to the exhaust fan when the system has been activated. Design to meet or exceeds NFPA Code 17-(Standard for Dry Chemical Extinguishing Systems), and NFPA 30-(Flammable and Combustible Liquids Code) Specifications.
- Canarm non-sparking Explosion-Proof Enclosed Exhaust Fan – 12in giving 1,640 CFM which exceeds NFPA 30.18.6.6.1 & NFPA 30.18.6.2.
- Built-in secondary Security 6in deep steel floor sump for spill containment.
- Floor grading support beams at 1 ft on Center.
- Galvanized grading is rated at 850 pounds per square foot.
- Removable Steel non-skid Floor Grating Provides Full Access to Secondary Containment.
- Interior Explosion Proof Lighting Class 1, Division 2.
- All applicable placards and stickers that include: No Smoking within 50 feet, NFPA diamond, NPPA Aluminum Flip File Placard, 10-Legend Worded Set, intended use Warning sticker, Warning Over Hang sticker.
- 4 top and bottom 4 bottom crane pad eyes.
- Forklift pockets: 96″ outside to outside of the forklift pockets / 67¾” inside to inside of the forklift pockets / 81½” center of the forklift pocket to center of the forklift pocket / Each forklift pocket is 14″ wide 4¼” tall.
- Premium, high-solids formula with acrylic polymers, resins, fillers, and titanium dioxide pigments white outside paint coating that Reflects 92% of solar heat and rays for a cooler inside temp.
- Vent openings are equipped with three-hour, UL Listed fire dampers, and foul weather hoods.
- Static Grounding system.
- 220V, Single-Phase 50-amp Electrical requirement. Each container will have a Marine Shore Power Inlet, model number RV129R, 50A 125/250Vac male electrical plug pre-installed near the unit’s power panel. We will provide a female Marine Shore Power Inlet, model number ED-RV129, 50A 125/250Vac plug that will need to be connected to a 4-wire SOOW cable. This cable must be provided by the customer. The unit must also be properly grounded by connecting a green ground wire coming out of the power panel to an 8′ copper grounding rod which must be driven down 95% in the ground. Each unit will be provided with one grounding rod and clamp.
- Built to comply with NFPA Code 17, 17A, 30, and 70 Specifications. Approved holding of hazardous and flammable materials in accordance with local regulations.
- AH 4-hour rated UL DES U419 / MEA 81-98-M walls & ceilings Class 1, Division 2 Compliant.
- Drum Capacity: 27.
- Pallet capacity 48″ x 40″: 8.
- Sump Capacity: 540.42 gallons.
- Wind Force Rating: 150mph.
- Side Door opening: 224″ wide x 84′ tall.
- End door opening: 92″ wide x 84′ tall.
- Exterior dimensions: 20ft long x 8ft wide x 8½ft tall ISO container. The electrical power panel and FSS alarm bell protrude an additional 6-½” giving a total length of 246-½”. The optional air conditioner unit if installed protrudes 15″ off the container’s back wall giving a total length of 255″.
- Interior dimensions: 216″ wide (201-½ to the fan) x 81″ deep x 86″ tall (74″ Floor to bottom of the light / 80-½” Floor to bottom of the FSS nozzles).
- GVW: 13,500 pounds.
- GVWR: 60,190 pounds.
- Liquid gallon capacity: 1,800 gallons.
- Lockable and Weatherproof Construction.
- 14-gauge corrugated steel.
- Pryo Chem Monarch PCI-35ABC Dry Chemical Total Flooding Fire Suppression System. Equipped with an external remote pull station, external audible alarm, and control head micro switch which cut power to the exhaust fan when the system has been activated. Design to meet or exceeds NFPA Code 17-(Standard for Dry Chemical Extinguishing Systems), and NFPA 30- (Flammable and Combustible Liquids Code) Specifications.
- Canarm non-sparking Explosion-Proof Enclosed Exhaust Fan – 12in giving 1,640 CFM which exceeds NFPA 30.18.6.6.1 & NFPA 30.18.6.2.
- Built-in secondary Security 6in deep steel floor sump for spill containment
- Floor grading support beams at 1 ft on Center.
- Galvanized grading is rated at 850 pounds per square foot.
- Removable Steel non-skid Floor Grating Provides Full Access to Secondary Containment.
- Interior Explosion Proof Lighting Class 1, Division 2.
- All applicable placards and stickers that include: No Smoking within 50 feet, NFPA diamond, NPPA Aluminum Flip File Placard, 10-Legend Worded Set, intended use Warning sticker, Warning Over Hang sticker.
- 4 top and bottom 4 bottom crane pad eyes.
- Forklift pockets: 96″ outside to outside of the forklift pockets / 67¾” inside to inside of the forklift pockets / 81½” center of the forklift pocket to center of the forklift pocket / Each forklift pocket is 14″ wide 4¼” tall.
- Premium, high-solids formula with acrylic polymers, resins, fillers, and titanium dioxide pigments white outside paint coating that Reflects 92% of solar heat and rays for a cooler inside temp.
- Vent openings are equipped with three-hour, UL Listed fire dampers, and foul weather hoods.
- Static Grounding system.
- 220V, Single-Phase 50-amp Electrical requirement. Each container will have a Marine Shore Power Inlet, model number RV129R, 50A 125/250Vac male electrical plug pre-installed near the unit’s power panel. We will provide a female Marine Shore Power Inlet, model number ED-RV129, 50A 125/250Vac plug that will need to be connected to a 4-wire SOOW cable. This cable must be provided by the customer. The unit must also be properly grounded by connecting a green ground wire coming out of the power panel to an 8′ copper grounding rod which must be driven down 95% in the ground. Each unit will be provided with one grounding rod and clamp.
- Built to comply with NFPA Code 17, 17A, 30, and 70 Specifications. Approved holding of hazardous and flammable materials in accordance with local regulations.
- Drum Capacity: 27-single stacked, 54-double stacked.
- Pallet capacity 48″ x 40″: 8-single stacked, 16-double stacked.
- Sump Capacity: 589 gallons.
- Wind Force Rating: 150mph.
- Side Door opening: 230″ wide x 96″ tall.
- End door opening: 102″ wide x 84″ tall.
- Exterior dimensions: 20′ long x 8′ wide x 9’6″ tall ISO container. The electrical power panel and FSS alarm bell protrude an additional 6-½” giving a total length of 246½”. The optional air conditioner unit if installed protrudes 20″ off the container’s back wall giving a total length of 260″.
- Interior dimensions: 235″ wide (221″ to the exhaust fan) x 92″ deep x 102½” tall (90½” Floor to bottom of the light / 97″ Floor to bottom of the FSS nozzles).
- GVW: 9,000 pounds.
- GVWR: 60,190 pounds.
- Liquid gallon capacity: 1,963.33 gallons.
- Lockable and Weatherproof Construction.
- 14-gauge corrugated steel.
- Pryo Chem Monarch PCI-35ABC Dry Chemical Total Flooding Fire Suppression System. Equipped with an external remote pull station, external audible alarm, and control head micro switch which cut power to the exhaust fan when the system has been activated. Design to meet or exceeds NFPA Code 17-(Standard for Dry Chemical Extinguishing Systems), and NFPA 30- (Flammable and Combustible Liquids Code) Specifications.
- Canarm non-sparking Explosion-Proof Enclosed Exhaust Fan – 12in giving 1,640 CFM which exceeds NFPA 30.18.6.6.1 & NFPA 30.18.6.2.
- Built-in secondary Security 6in deep steel floor sump for spill containment.
- Floor grading support beams at 1 ft on Center.
- Galvanized grading is rated at 850 pounds per square foot.
- Removable Steel non-skid Floor Grating Provides Full Access to Secondary Containment.
- Interior Explosion Proof Lighting Class 1, Division 2.
- All applicable placards and stickers that include: No Smoking within 50 feet, NFPA diamond, NPPA Aluminum Flip File Placard, 10-Legend Worded Set, intended use Warning sticker, Warning Over Hang sticker.
- 4 top and bottom 4 bottom crane pad eyes.
- Forklift pockets: 96″ outside to outside of the forklift pockets / 67¾” inside to inside of the forklift pockets / 81½” center of the forklift pocket to center of the forklift pocket / Each forklift pocket is 14″ wide 4¼” tall.
- Premium, high-solids formula with acrylic polymers, resins, fillers, and titanium dioxide pigments white outside paint coating that Reflects 92% of solar heat and rays for a cooler inside temp.
- Vent openings are equipped with foul-weather hoods.
- Static Grounding system.
- 220V, Single-Phase 50-amp Electrical requirement. Each container will have a Marine Shore Power Inlet, model number RV129R, 50A 125/250Vac male electrical plug pre-installed near the unit’s power panel. We will provide a female Marine Shore Power Inlet, model number ED-RV129, 50A 125/250Vac plug that will need to be connected to a 4-wire SOOW cable. This cable must be provided by the customer. The unit must also be properly grounded by connecting a green ground wire coming out of the power panel to an 8′ copper grounding rod which must be driven down 95% in the ground. Each unit will be provided with one grounding rod and clamp.
- Built to comply with NFPA Code 17, 17A, 30, and 70 Specifications. Approved holding of hazardous and flammable materials in accordance with local regulations.
- AH 4-hour rated UL DES U419 / MEA 81-98-M walls & ceilings Class 1, Division 2 Compliant.
- Drum Capacity: 27 single-stacked, 54 double-stacked.
- Pallet capacity 48″ x 40″: 8 single-stacked, 16 double-stacked.
- Sump Capacity: 540.42 gallons.
- Wind Force Rating: 150mph.
- Side Door opening: 224″ wide x 97″ tall.
- End door opening: 92″ wide x 98″ tall.
- Exterior dimensions: 20ft long x 8ft wide x 9½ft tall ISO container. The electrical power panel and FSS alarm bell protrude an additional 6-½” giving a total length of 246-½”. The optional air conditioner unit if installed protrudes 15″ off the container’s back wall giving a total length of 255″.
- Interior dimensions: 222-½” deep (208″ to the fan) x 81″ x 98½” tall (86½” Floor to bottom of the light / 93″ Floor to bottom of the FSS nozzles).
- GVW: 14,600 pounds.
- GVWR: 60,190 pounds.
- Liquid gallon capacity: 1,800 gallons.
- Lockable and Weatherproof Construction.
- 14-gauge corrugated steel.
- Pryo Chem Monarch PCI-35ABC Dry Chemical Total Flooding Fire Suppression System. Equipped with an external remote pull station, external audible alarm, and control head micro switch which cut power to the exhaust fan when the system has been activated. Design to meet or exceeds NFPA Code 17-(Standard for Dry Chemical Extinguishing Systems), and NFPA 30- (Flammable and Combustible Liquids Code) Specifications.
- Canarm non-sparking Explosion-Proof Enclosed Exhaust Fan – 12in giving 1,640 CFM which exceeds NFPA 30.18.6.6.1 & NFPA 30.18.6.2.
- Built-in secondary Security 6in deep steel floor sump for spill containment.
- Floor grading support beams at 1 ft on Center.
- Galvanized grading is rated at 850 pounds per square foot.
- Removable Steel non-skid Floor Grating Provides Full Access to Secondary Containment.
- Interior Explosion Proof Lighting Class 1, Division 2.
- All applicable placards and stickers that include: No Smoking within 50 feet, NFPA diamond, NPPA Aluminum Flip File Placard, 10-Legend Worded Set, intended use Warning sticker, Warning Over Hang sticker.
- 4 top and bottom 4 bottom crane pad eyes.
- Forklift pockets: 96″ outside to outside of the forklift pockets / 67¾” inside to inside of the forklift pockets / 81½” center of the forklift pocket to center of the forklift pocket / Each forklift pocket is 14″ wide 4¼” tall.
- Premium, high-solids formula with acrylic polymers, resins, fillers, and titanium dioxide pigments white outside paint coating that Reflects 92% of solar heat and rays for a cooler inside temp.
- Vent openings are equipped with two-hour, UL Listed fire dampers, and foul weather hoods.
- Static Grounding system.
- 220V, Single-Phase 50-amp Electrical requirement. Each container will have a Marine Shore Power Inlet, model number RV129R, 50A 125/250Vac male electrical plug pre-installed near the unit’s power panel. We will provide a female Marine Shore Power Inlet, model number ED-RV129, 50A 125/250Vac plug that will need to be connected to a 4-wire SOOW cable. This cable must be provided by the customer. The unit must also be properly grounded by connecting a green ground wire coming out of the power panel to an 8′ copper grounding rod which must be driven down 95% in the ground. Each unit will be provided with one grounding rod and clamp.
- Built to comply with NFPA Code 17, 17A, 30, and 70 Specifications. Approved holding of hazardous and flammable materials in accordance with local regulations.
- AH 2-hour rated UL DES U419 / MEA 81-98-M walls & ceilings Class 1, Division 2 Compliant.
- Drum Capacity: 27 single-stacked, 54 double stacked.
- Pallet capacity 48″ x 40″: 8 single-stacked, 16 double stacked.
- Sump Capacity: 540.42 gallons.
- Wind Force Rating: 150mph.
- Side Door opening: 224″ wide x 97″ tall.
- End door opening: 92″ wide x 98″ tall.
- Exterior dimensions: 20ft long x 8ft wide x 9’6″ ft tall ISO container. The electrical power panel and FSS alarm bell protrude an additional 6-½” giving a total length of 246-½”. The optional air conditioner unit if installed protrudes 15″ off the container’s back wall giving a total length of 255″.
- Interior dimensions: 216″ wide (201-½ to the fan) x 82″ deep x 98-½” tall (86-½” Floor to bottom of the light / 93″ Floor to bottom of the FSS nozzles).
- GVW: 14,600 pounds.
- GVWR: 60,190 pounds.
- Liquid gallon capacity: 1,800 gallons.
- Lockable and Weatherproof Construction.
- 14-gauge corrugated steel.
- Pryo Chem Monarch PCI-35ABC Dry Chemical Total Flooding Fire Suppression System. Equipped with an external remote pull station, external audible alarm, and control head micro switch which cut power to the exhaust fan when the system has been activated. Design to meet or exceeds NFPA Code 17-(Standard for Dry Chemical Extinguishing Systems), and NFPA 30- (Flammable and Combustible Liquids Code) Specifications.
- Canarm non-sparking Explosion-Proof Enclosed Exhaust Fan – 12in giving 1,640 CFM which exceeds NFPA 30.18.6.6.1 & NFPA 30.18.6.2.
- Built-in secondary Security 6in deep steel floor sump for spill containment.
- Floor grading support beams at 1 ft on Center.
- Galvanized grading is rated at 850 pounds per square foot.
- Removable Steel non-skid Floor Grating Provides Full Access to Secondary Containment.
- Interior Explosion Proof Lighting Class 1, Division 2.
- All applicable placards and stickers that include: No Smoking within 50 feet, NFPA diamond, NPPA Aluminum Flip File Placard, 10-Legend Worded Set, intended use Warning sticker, Warning Over Hang sticker.
- 4 top and bottom 4 bottom crane pad eyes.
- Forklift pockets: 96″ outside to outside of the forklift pockets / 67¾” inside to inside of the forklift pockets / 81½” center of the forklift pocket to center of the forklift pocket / Each forklift pocket is 14″ wide 4¼” tall.
- Premium, high-solids formula with acrylic polymers, resins, fillers, and titanium dioxide pigments white outside paint coating that Reflects 92% of solar heat and rays for a cooler inside temp.
- Vent openings are equipped with three-hour, UL Listed fire dampers, and foul weather hoods.
- Static Grounding system.
- 220V, Single-Phase 50-amp Electrical requirement. Each container will have a Marine Shore Power Inlet, model number RV129R, 50A 125/250Vac male electrical plug pre-installed near the unit’s power panel. We will provide a female Marine Shore Power Inlet, model number ED-RV129, 50A 125/250Vac plug that will need to be connected to a 4-wire SOOW cable. This cable must be provided by the customer. The unit must also be properly grounded by connecting a green ground wire coming out of the power panel to an 8′ copper grounding rod which must be driven down 95% in the ground. Each unit will be provided with one grounding rod and clamp.
- Built to comply with NFPA Code 17, 17A, 30, and 70 Specifications. Approved holding of hazardous and flammable materials in accordance with local regulations.